These Annular transducers are designed to fit directly to Norbar gearboxes in the 'Standard Series' (PneuTorque, EvoTorque and HandTorque) and will accurately measure the torque output via a display instrument.
                        
                        
                            - Part number:
                                50638.LOG
                            
 
                            - EAN Bar Code:
                                5060922233318
                            
 
                            - NATO number:
                                -
                            
 
                            - Accuracy:
                                ±0.5%
                            
 
                            - Operates between:
                                
                                        100.00 -
												        1000.00
                                        N·m
                                        
                                        
                                    
                             
                        
                        
                        
                        
                        
                            
                                
                                Compare Products
                                Please select further products to compare.
                             
                         
                        
                            
                                
                                    - Features
                                        
                                            
                                            
                                                
                                                    
                                                            - 
                                                                Designed to ignore non torsional forces.
                                                            
 
                                                        
                                                            - 
                                                                Robust heat treated alloy steel torsion tube design.
                                                            
 
                                                        
                                                            - 
                                                                'SMART' transducers can also be used with many instruments not of Norbar manufacture. However, these will operate as normal ratio calibrated (mV/V) transducers - the 'SMART' data will not be read. For non Norbar instruments or for when a mV/V certificate is required, use part code suffix '.IND'.
                                                            
 
                                                        
                                                
                                             
                                         
                                     
                                    - Technical Specifications
                                        
                                            
                                            
                                                
                                                    
                                                            - 
                                                                Weight: 1.4 Kg
                                                            
 
                                                        
                                                            - 
                                                                Type: Standard
                                                            
 
                                                        
                                                            - 
                                                                Temp Range Operating: -10°C to +50°C
                                                            
 
                                                        
                                                            - 
                                                                Temp Range Storage: -20°C to +70°C
                                                            
 
                                                        
                                                            - 
                                                                Thermal Effect On Span: < +/- 0.03%/°C
                                                            
 
                                                        
                                                            - 
                                                                Thermal Effect On Zero: < +/- 0.01%/°C
                                                            
 
                                                        
                                                            - 
                                                                Max Torsion Of Capacity: 150% of rated torque
                                                            
 
                                                        
                                                            - 
                                                                Torsional Deflection: < 1°
                                                            
 
                                                        
                                                            - 
                                                                Fatigue: > 10 exp 7 cycles