Calibration Disc

  • The <0.02% uncertainty of applied torque achievable with this disc allows calibration to the highest class of accuracy specified by BS7882:2008.
  • Machined to +/-0.01% (100 microns per meter) from aircraft alloys.
  • Clockwise and counter-clockwise operation.
  • Capable of SI or Imperial calibrations.
  • Compatible with male and female 1/4" square transducer drives.
  • No bearings to cause energy loss during loading.
  • Brass weights with an accuracy better than +/-0.01% are available in five sets to achieve a variety of calibration ranges.
  • Special weight sets can be specified up to a maximum torque of 2.5 N.m.

Radius Ended Beams

  • The <0.02% uncertainty of applied torque achievable with these beams allows calibration to the highest class of accuracy specified by BS7882:2008.
  • Machined to +/-0.01% (100 microns per meter) from aircraft alloys.
  • Clockwise and Counter-clockwise operation.
  • All have interchangeable square drive to increase flexibility of use.
  • Torque radius maintained throughout +/-8 degrees of rotation from horizontal.
  • No bearings to cause energy loss during loading.
  • Balanced to maximise energy transfer to transducer during loading.
  • Loading point offset to reduce bending moments on the transducer.
  • High torque accuracy allows use of cast iron weights rather than stainless steel. Weight accuracy is required to be equal to or better than +/-0.01%.

5000 lbf.ft Calibration Beam

  • The <0.04% uncertainty of applied torque achievable with this beam allows calibration to the high classes of accuracy specified by BS7882:2008.
  • Beam length machined to +/-0.01% (100 microns per meter).
  • Clockwise and Counter-clockwise operation.
  • Beams balanced to maximise energy transfer to transducer during loading.
  • High beam accuracy allows use of cast iron weights rather than stainless steel. Weight accuracy is required to be equal to or better than 0.01%.
  • High quality bearings to reduce energy losses.
  • Gearbox provided to level beam and remove cosine errors.
  • SI and Imperial Calibration possible with one beam (using different weights).

Calibration Disc; 100mm radius
Part No. 21400

Designed to remove potential sources of measurement error, these Discs can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each Disc. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


Calibration Beam; Radius Ended, Unsupported, 0.5 - 50 N.m
Part No. 21420

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


Calibration Beam; Radius Ended, Unsupported, 5 - 100 N.m
Part No. 21421

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


Calibration Beam; Radius Ended, Unsupported, 5 - 500 N.m
Part No. 24127

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


Calibration Beam; Radius Ended, Unsupported, 10 - 1500 N.m
Part No. 21428

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. Traceable length certificate is provided with each beam.


Calibration Beam; Radius Ended, Unsupported, 10 - 500 lbf.in
Part No. 21423

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


Calibration Beam; Radius Ended, Unsupported, 10 - 100 lbf.ft
Part No. 21424

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


Calibration Beam; Radius Ended, Unsupported, 50 - 500 lbf.ft
Part No. 21425

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


Calibration Beam; Radius Ended, Unsupported, 100 - 1000 lbf.ft
Part No. 21426

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


Calibration Beam; Free Standing, 500-5000 N.m/lbf.ft
Part No. 21842

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


10 x 0.5 N Weights
Part No. 21452

Weight accuracy is equal to or better than 0.01%.


10 x 1.27 ozf Weights
Part No. 21455

Weight accuracy is equal to or better than 0.01%.


10 x 2.54 ozf Weights
Part No. 21453

Weight accuracy is equal to or better than 0.01%.


10 x 4.064 ozf Weights
Part No. 21451

Weight accuracy is equal to or better than 0.01%.


10 x 2 N Weights
Part No. 21476

Weight accuracy is equal to or better than 0.01%.


10 x 4.0 N Weights
Part No. 21454

Weight accuracy is equal to or better than 0.01%.


10 x 10 N Weights
Part No. 21477

Weight accuracy is equal to or better than 0.01%.


10 x 20.0 N Weights
Part No. 21458

Weight accuracy is equal to or better than 0.01%.


1 x 10 N, 10 x 50 N Weights
Part No. 21459

Weight accuracy is equal to or better than 0.01%.


1 x 10.0 N, 10 x 100.0 N Weights
Part No. 21460

Weight accuracy is equal to or better than 0.01%.


14 x 100 N, 2 x 50 N, 1 X 10 N Weights
Part No. 21483

Weight accuracy is equal to or better than 0.01%.


10 x 1.0 lbf Weights
Part No. 21465

Weight accuracy is equal to or better than 0.01%.


10 x 5.0 lbf Weights
Part No. 21466

Weight accuracy is equal to or better than 0.01%.


10 x 10.0 lbf Weights
Part No. 21467

Weight accuracy is equal to or better than 0.01%.


10 x 25.0 lbf Weights
Part No. 21468

Weight accuracy is equal to or better than 0.01%.


20 x 50 lbf Weights
Part No. 21469

Weight accuracy is equal to or better than 0.01%.


10 x 20 Kg Weights
Part No. 21462

Weight accuracy is equal to or better than 0.01%.


10 x 1.0 N Weights
Part No. 21450

Weight accuracy is equal to or better than 0.01%.


Calibration Beam; Free Standing (obsolete)
Part No. 21515

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.


(Obsolete) Calibration Beam; Radius Ended, Unsupported, 10 - 1000 N.m (superseded by 21428)
Part No. 21422

Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam. Note: A temperature controlled environment is essential for use of these beams. The selection of weights will be influenced by gravitational constant and air buoyancy values at the proposed laboratory site.

  Engineer to Order

  Product Catalogues & Handbooks 

  Typical Applications

 Print   

  Copyright © Norbar Torque Tools Ltd. All Rights Reserved.
 Terms Of Use     Privacy Statement     Site Map 

NORBAR TORQUE TOOLS LTD, Beaumont Road, Banbury, Oxfordshire, OX16 1XJ, United Kingdom
Tel + 44 (0) 1295 753600  Enquiries + 44 (0) 1295 270333  Fax + 44 (0) 1295 753643  Email enquiry@norbar.com
Registered Office as above - Registered in England No. 380480 - VAT No. GB 119 1060 05